WWW.AVTOAKPP-CVT.COM   INDEPENDENT REPAIR VARIATOR VT25-E/VT20-E. SATURN. OPEL.





 





                                                     CHECKING THE SOLENOIDS

 

   At the end of the solenoid is a screw with a hexagon, while turning the screw clockwise

decreases volume of discharge (the pressure will increase), while turning counterclockwise

discharge volume will be increased (the pressure will decrease).

 

  In the picture: the unit solenoids and valve block.

  1- solenoid "LINE PRESSURE CONTROL SOLENOID VALVE",

  2- screw for adjusting the pressure in the main thoroughfare,

  3- stepper motor "RATIO CONTROL MOTOR",

  4- lever that connects the stepper motor with a movable cone drive shaft,

  5- valve "VARIABLE RATIO CONTROL",

  6- solenoid "NEUTRAL IDLE/TCC ON - OFF SOLENOID VALVE",

  7- solenoid "NEUTRAL IDLE/TCC CLUTCH CONTROL SOLENOID VALVE",

  8- block solenoids,

  9- valve block,

  10- tube with gaskets that hold the valve,

  11- strip between the blocks of solenoids and valves.

 

                                                      Page 1  3 4

 

                                                           -2-

 

  









Copyright © inside repair of variator VT25-E/VT20-E, 2011. All Of rights Of reserved